Part Number
Definition:
A TRANSFORMER CONSISTING OF ONE OR MORE PRIMARY WINDING(S) AND ONE OR MORE SECONDARY WINDING(S). IT MAY BE DESIGNED FOR DIRECT CONNECTION TO AN ALTERNATING CURRENT SOURCE FOR PURPOSES OF CHANGING THE SECONDARY VOLTS AND AMPERES OR DESIGNED TO ELIMINATE METALLIC INTERCONNECTION BETWEEN CIRCUITS IN AN OVERALL ONE TO ONE VOLTAGE RATIO, WITH OR WITHOUT ADDITIONAL OUTPUT WINDINGS, OR ITEMS DESIGNED TO AUTOMATICALLY MAINTAIN A CONSTANT OUTPUT VOLTAGE WITHIN SPECIFIED LIMITS UNDER VARYING INPUT OR LOAD CONDITIONS. ALSO INCLUDES ITEMS HAVING A PROVISION FOR MECHANICALLY CHANGING THE TURNS RATIO OR INDUCTIVE COUPLING IN PROGRESSIVE INCREMENTS BY MEANS OF VOLTAGE TAPS, RATIO ADJUSTER, OR DEVICES OE SIMILAR DESIGN. FOR TRANSFORMERS HAVING WINDING(S) COMMON TO BOTH INPUT AND OUTPUT CIRCUITS, SEE TRANSFORMER (1), POWER, AUTOTRANSFORMER. EXCLUDES TRANSFORMER (1), PULSE.
CAGE Information
Code | Company |
---|---|
62274 | EMERSON ELECTRIC CO. DIV WHITE-RODGE |
Federal Supply Class
Title
COILS AND TRANSFORMERS
Inclusions:
INCLUDES COILS, EXCEPT IGNITION AND MAGNETO; COIL ASSEMBLIES; REACTORS; TRANSFORMERS.
Exclusions:
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
AKPV | MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP |
ABMK | OVERALL WIDTH | 3.438 INCHES NOMINAL |
PKWT | UNPACKAGED UNIT WEIGHT (NON-CORE) | 7.000 POUNDS |
AXGY | MOUNTING METHOD | BRACKET SINGLE GROUP AND SLOT SINGLE GROUP |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 2.625 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
CWJS | WINDING OPERATING VOLTAGE | 28.00 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 6.0 AMPERES NOMINAL B AND BETTER DROP SIDING SINGLE COMPONENT SINGLE SECONDARY |
ABHP | OVERALL LENGTH | 3.500 INCHES NOMINAL |
CBME | CUBIC MEASURE (NON-CORE) | 50.4 CUBIC INCHES |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
ACZB | FREQUENCY RATING | 50.0 HERTZ NOMINAL SINGLE COMPONENT OR 60.0 HERTZ NOMINAL SINGLE COMPONENT |
BPLC | WINDING FUNCTION AND QUANTITY | 1 PRIMARY SINGLE COMPONENT AND 1 SECONDARY SINGLE COMPONENT |
CQLC | WINDING TAP LOCATION (NON-CORE) | CENTER TAP SINGLE COMPONENT SINGLE SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 117.00 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE PRIMARY |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
TTQY | TERMINAL TYPE AND QUANTITY | 5 WIRE LEAD |
ABKW | OVERALL HEIGHT | 4.188 INCHES NOMINAL |
AKNA | INCLOSURE TYPE | OPEN |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 2.750 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ABTD | MOUNTING SLOT WIDTH | 0.262 INCHES NOMINAL SINGLE GROUP |