Part Number
Part Number:
NSN:
NIIN:
Item Name:
REACTOR-TRANSFORMER
Definition:
A COMPONENT CONSISTING OF TWO OR MORE ELECTRICALLY DISTINCT ITEMS. ONE OR MORE ITEMS ARE MADE OF ONE OR MORE COILS WHICH FUNCTION AS A REACTOR; AT LEAST ONE OTHER ITEM IS MADE OF A TAPPED COIL OR TWO OR MORE COILS WHICH FUNCTION AS A TRANSFORMER. THE ITEMS MAY HAVE A COMMON CORE, BUT ARE NOT MAGNETICALLY COUPLED.
CAGE Information
Code | Company |
---|---|
80023 | HIREL SYSTEMS LLC |
Federal Supply Class
Title
COILS AND TRANSFORMERS
Inclusions:
INCLUDES COILS, EXCEPT IGNITION AND MAGNETO; COIL ASSEMBLIES; REACTORS; TRANSFORMERS.
Exclusions:
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
BKPL | RATING METHOD | ELECTRICAL 1ST COMPONENT SINGLE SECONDARY |
BKPL | RATING METHOD | ELECTRICAL 1ST COMPONENT SINGLE SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 10.00 AC POUNDS PER HOUR WET 1ST COMPONENT SINGLE SECONDARY |
TTQY | TERMINAL TYPE AND QUANTITY | 11 STANDOFF, THREADED STUD |
ACZB | FREQUENCY RATING | 2.4 KILOHERTZ NOMINAL 2ND COMPONENT |
CRGS | DC RESISTANCE RATING IN OHMS | 0.006 2ND COMPONENT SINGLE WINDING |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 5.420 INCHES MINIMUM ALL MOUNTING FACILITIES SINGLE CENTER GROUP AND 5.460 INCHES MAXIMUM ALL MOUNTING FACILITIES SINGLE CENTER GROUP |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | THREE PHASE TO THREE PHASE 1ST COMPONENT |
ADAT | BODY WIDTH | 6.650 INCHES MAXIMUM |
AEHZ | MAXIMUM OPERATING TEMP | 105.0 DEG CELSIUS |
CRBZ | WINDING OPERATING CURRENT | 60.5 AMPERES NOMINAL B AND BETTER DROP SIDING 1ST COMPONENT SINGLE SECONDARY |
AXGY | MOUNTING METHOD | THREADED HOLE ALL GROUPINGS |
CQJX | NOMINAL THREAD SIZE | 0.250 INCHES ALL GROUPINGS |
ADAQ | BODY LENGTH | 7.920 INCHES MAXIMUM |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
ACZB | FREQUENCY RATING | 360.0 HERTZ MINIMUM 1ST COMPONENT AND 440.0 HERTZ MAXIMUM 1ST COMPONENT |
CRBZ | WINDING OPERATING CURRENT | 80.0 AMPERES MAXIMUM OF STANDARD RANGE B AND BETTER DROP SIDING 2ND COMPONENT SINGLE WINDING |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 6.690 INCHES MAXIMUM ALL MOUNTING FACILITIES SINGLE CENTER GROUP |
ACYV | INDUCTANCE RATING | 0.80 MILLIHENRIES MINIMUM 2ND COMPONENT SINGLE WINDING |
AKNA | INCLOSURE TYPE | HERMETICALLY SEALED WITH OIL |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE PHASE TO SINGLE PHASE 2ND COMPONENT |
CWJS | WINDING OPERATING VOLTAGE | 120.00 AC POUNDS PER HOUR WET 1ST COMPONENT SINGLE PRIMARY OR 208.00 AC POUNDS PER HOUR WET 1ST COMPONENT SINGLE PRIMARY |
BPLC | WINDING FUNCTION AND QUANTITY | 1 PRIMARY 1ST COMPONENT AND 1 SECONDARY 1ST COMPONENT |
CWJS | WINDING OPERATING VOLTAGE | 0.70 AC POUNDS PER HOUR WET 2ND COMPONENT SINGLE WINDING |
ACZX | WINDING SHIELDING METHOD | INTERNAL SHIELD GROUNDED TO INCLOSURE SINGLE COMPONENT |
BKPL | RATING METHOD | ELECTRICAL 1ST COMPONENT SINGLE PRIMARY |
THSD | THREAD SERIES DESIGNATOR | UNC ALL GROUPINGS |
AKPV | MOUNTING FACILITY QUANTITY | 8 ALL GROUPINGS |
CMLP | THREAD QUANTITY PER INCH | 20 ALL GROUPINGS |
ABKW | OVERALL HEIGHT | 7.310 INCHES MAXIMUM |
BKPL | RATING METHOD | ELECTRICAL 2ND COMPONENT SINGLE WINDING |