Definition:
AN ITEM WHICH, WHEN INTERFACED WITH A CALIBRATOR SET, X-RAY SYSTEM, AFFORDS INVASIVE COMPLIANCE TESTING CAPABILITIES IN ACCORDANCE WITH REGULATIONS GOVERNING STATIONARY RADIOGRAPHIC AND FLUOROSCOPIC X-RAY SYSTEMS. IT IS DESIGNED PRIMARILY TO CONVERT X-RAY GENERATOR PEAK KILOVOLTAGE, MILLIAMPERES, AND/OR X-RAY TUBE FILAMENT CURRENT TO LOW VOLTAGE SIGNALS WHICH MAY BE MONITORED BY EXTERNAL EQUIPMENT. IT MAY HAVE THE CAPABILITY TO ANALYZE AND/OR TROUBLESHOOT SYSTEM PROBLEMS WHEN INTERFACED WITH CERTAIN OPERATING COMPONENTS SUPPLIED SEPARATELY OR ALREADY PRESENT AT THE POINT OF USAGE.
CAGE Information
Code | Company |
---|---|
3B150 | RAYTHEON TECHNICAL SERVICES COMPANY |
Federal Supply Class
Title
IMAGING EQUIPMENT AND SUPPLIES:
Inclusions:
INCLUDES MEDICAL X-RAY FILM; MEDICAL X-RAY FILM VIEWING EQUIPMENT; MEDICAL X-RAY FILM PROCESSING AND FINISHING EQUIPMENT AND SUPPLIES; X-RAY TUBES; COMPUTERIZED TOMOGRAPHY (CT) SCANNERS AND RELATED EQUIPMENT; MAGNETIC RESONANCE IMAGING MACHINE AND RELATED EQUIPMENT; POSITRON EMISSION TOMOGRAPHY (PET) SCANNERS AND RELATED EQUIPMENT; COMPUTED AND/OR DIRECT DIGITAL RADIOGRAPHY MACHINES AND RELATED EQUIPMENT; ULTRASOUND AND ECHOCARDIOGRAM SCANNERS AND RELATED EQUIPMENT; SCINTIGRAPHY EQUIPMENT; MEDICAL PICTURE ARCHIVING AND COMMUNICATION SYSTEMS (PACS) EQUIPMENT; MEDICAL THERMAL IMAGING EQUIPMENT; OPTICAL COHERENCE TOMOGRAPHY (OCT) SPECTROSCOPY MACHINES AND RELATED EQUIPMENT; AND IMAGING SUPPLIES AND CONTRAST DELIVERY SYSTEMS THAT ARE NOT USED BY OTHER MEDICAL DISCIPLINES.
Exclusions:
EXCLUDES INDUSTRIAL IMAGING EQUIPMENT (X-RAY, THERMAL AND THE REST;) SUPPLIES AND EQUIPMENT THAT CAN BE USED BY OTHER MEDICAL DISCIPLINES (SEE MEDICAL AND SURGICAL INSTRUMENTS, EQUIPMENT AND SUPPLIES AND HOSPITAL AND SURGICAL CLOTHING AND RELATED SPECIAL PURPOSE ITEMS.)
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
TEXT | GENERAL CHARACTERISTICS ITEM DESCRIPTION | REPLACEMENT UNIT FOR CALIBRATOR SET,6525-01-151-6400; CONVERTS X-RAY GENERATOR HIGH TENSION KVP,MA AND X-RAY TUBE FILAMENT CURRENTS TO LOW VOLTAGE SHOCKPROOF SIGNALS; HIGH VOLTAGE DIVIDER NETWORK PROVIDES FREQUENCY RESPONSE OF PORM 1DB FROM 0 TO 100 KHZ; ANODE CURRENT SENSOR PROVIDES AN ISOLATED SIGNAL REPRESENTING ANODE WAVEFORM AND MEASURES CURRENT W/I RANGE OF 1 MA TO 2 AMPERES W/2 PCT ACCURACY FOR GREATER THAN 10 MA; X-RAY TUBE FILAMENT CURRENT MONIOR MEASURES CURRENTS UP TO 20 AMPERES W/ACCURACY OF PORM 1 PCT AT 60 HZ; 2 5 FT CABLES; OPERATES ON 115/230 VOLTS,50/60 HZ,AC; W/CARRYING CASE; FOR REPLACEMENT CABLE USE 6525-01-076-4716 |
SUCB | UNIT OF ISSUE CUBE | 4.10 CUBIC FEET |
CXCY | PART NAME ASSIGNED BY CONTROLLING AGENCY | HIGH VOLTAGE DIVIDER UNIT X-RAY SYS CAL SET 115/230V50-60HZ AC |
ECWT | EXTERIOR CONTAINER WEIGHT | 45.00 POUNDS |