Part Number
Definition:
A TRANSFORMER CONSISTING OF ONE OR MORE PRIMARY WINDING(S) AND ONE OR MORE SECONDARY WINDING(S). IT MAY BE DESIGNED FOR DIRECT CONNECTION TO AN ALTERNATING CURRENT SOURCE FOR PURPOSES OF CHANGING THE SECONDARY VOLTS AND AMPERES OR DESIGNED TO ELIMINATE METALLIC INTERCONNECTION BETWEEN CIRCUITS IN AN OVERALL ONE TO ONE VOLTAGE RATIO, WITH OR WITHOUT ADDITIONAL OUTPUT WINDINGS, OR ITEMS DESIGNED TO AUTOMATICALLY MAINTAIN A CONSTANT OUTPUT VOLTAGE WITHIN SPECIFIED LIMITS UNDER VARYING INPUT OR LOAD CONDITIONS. ALSO INCLUDES ITEMS HAVING A PROVISION FOR MECHANICALLY CHANGING THE TURNS RATIO OR INDUCTIVE COUPLING IN PROGRESSIVE INCREMENTS BY MEANS OF VOLTAGE TAPS, RATIO ADJUSTER, OR DEVICES OE SIMILAR DESIGN. FOR TRANSFORMERS HAVING WINDING(S) COMMON TO BOTH INPUT AND OUTPUT CIRCUITS, SEE TRANSFORMER (1), POWER, AUTOTRANSFORMER. EXCLUDES TRANSFORMER (1), PULSE.
CAGE Information
Code | Company |
---|---|
96256 | THORDARSON INC |
Federal Supply Class
Title
COILS AND TRANSFORMERS
Inclusions:
INCLUDES COILS, EXCEPT IGNITION AND MAGNETO; COIL ASSEMBLIES; REACTORS; TRANSFORMERS.
Exclusions:
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
CQLC | WINDING TAP LOCATION (NON-CORE) | CENTER TAP SINGLE COMPONENT 3RD SECONDARY |
AKPV | MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP |
CWJS | WINDING OPERATING VOLTAGE | 34.00 AC POUNDS PER HOUR WET SINGLE COMPONENT 1ST SECONDARY |
CQLC | WINDING TAP LOCATION (NON-CORE) | TAP W/O CENTER TAP SINGLE COMPONENT SINGLE PRIMARY |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 2.850 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
CRMJ | WINDING POWER RATING | 1.72 VOLTS-AMPERES SINGLE COMPONENT 3RD SECONDARY |
CQLC | WINDING TAP LOCATION (NON-CORE) | CENTER TAP SINGLE COMPONENT 4TH SECONDARY |
CRMJ | WINDING POWER RATING | 1.72 VOLTS-AMPERES SINGLE COMPONENT 4TH SECONDARY |
AXGY | MOUNTING METHOD | SLOT SINGLE GROUP |
CWJS | WINDING OPERATING VOLTAGE | 34.00 AC POUNDS PER HOUR WET SINGLE COMPONENT 2ND SECONDARY |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 3.000 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
CWJS | WINDING OPERATING VOLTAGE | 43.00 AC POUNDS PER HOUR WET SINGLE COMPONENT 4TH SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 40.0 MILLIAMPERES NOMINAL B SINGLE COMPONENT 3RD SECONDARY |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
CRBZ | WINDING OPERATING CURRENT | 40.0 MILLIAMPERES NOMINAL B SINGLE COMPONENT 4TH SECONDARY |
AKNA | INCLOSURE TYPE | HERMETICALLY SEALED |
TTQY | TERMINAL TYPE AND QUANTITY | 13 TURRET |
CWJS | WINDING OPERATING VOLTAGE | 115.00 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE PRIMARY AND 120.00 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE PRIMARY |
ABTD | MOUNTING SLOT WIDTH | 0.219 INCHES NOMINAL SINGLE GROUP |
CRMJ | WINDING POWER RATING | 115.6 VOLTS-AMPERES SINGLE COMPONENT 1ST SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 3.4 AMPERES NOMINAL B SINGLE COMPONENT 1ST SECONDARY |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
CRMJ | WINDING POWER RATING | 115.6 VOLTS-AMPERES SINGLE COMPONENT 2ND SECONDARY |
ADAT | BODY WIDTH | 3.750 INCHES MAXIMUM |
CRBZ | WINDING OPERATING CURRENT | 3.4 AMPERES NOMINAL B SINGLE COMPONENT 2ND SECONDARY |
ADAU | BODY HEIGHT | 4.620 INCHES MAXIMUM |
CWJS | WINDING OPERATING VOLTAGE | 43.00 AC POUNDS PER HOUR WET SINGLE COMPONENT 3RD SECONDARY |
ACZB | FREQUENCY RATING | 60.0 HERTZ NOMINAL SINGLE COMPONENT |
ADAQ | BODY LENGTH | 3.880 INCHES MAXIMUM |
BPLC | WINDING FUNCTION AND QUANTITY | 1 PRIMARY SINGLE COMPONENT AND 4 SECONDARY SINGLE COMPONENT |