Part Number
Part Number:
NSN:
NIIN:
Item Name:
LOAD CELL , FORCE-WEIGHT
Definition:
AN ELECTRICALLY OPERATED STRAIN-GAGE DEVICE USED TO CHANGE PHYSICAL FORCE(S), SUCH AS WEIGHT OR THRUST TO AN ELECTRICAL SIGNAL WHICH IS TRANSMITTED TO READ-OUT DEVICE, SUCH AS A COUNTER, INDICATOR, METER, RECORDING OSCILLOGRAPH, OR THE LIKE.
CAGE Information
Code | Company |
---|---|
01HT4 | HOTTINGER BALDWIN MEASUREMENTS INC. |
Federal Supply Class
Title
SCALES AND BALANCES
Inclusions:
INCLUDES COIN OPERATED, HOUSEHOLD, INDUSTRIAL, POSTAL, AND LABORATORY SCALES AND BALANCES.
Exclusions:
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
AGAV | END ITEM IDENTIFICATION | PART OF A/E40T-1 ELECTRO-OPTICAL SYSTEM COMPONENTS TEST STAND NEXT HIGHER ASSEMBLY IS THE WM1 CENTER OF GRAVITY WEIGHING SCALE |
ACDC | CURRENT TYPE | DC |
ASSB | MECHANICAL CONNECTION QUANTITY | 1 |
BGST | PRESSURE RATING | 127.000 POUNDS PER SQUARE INCH NOMINAL |
ABKW | OVERALL HEIGHT | 62.2 MILLIMETERS NOMINAL |
FEAT | SPECIAL FEATURES | MECHANICAL CONNECTION STRAIGHT ROD APPXOIMATELY 10MM LONG BY 2.5MM DIA;WITH INDENT FOR COUPLING ADAPTERS, HAS 2 M5X8MM SCREW HOLES FOR MOUNTING ON BASE. 6 METER LONG CALBLE. |
ADAV | OVERALL DIAMETER | 49.5 MILLIMETERS NOMINAL |
BKFB | EXTERNAL DC OPERATING VOLTAGE IN VOLTS | 0.5 MINIMUM SINGLE VOLTAGE AND 6.0 MAXIMUM SINGLE VOLTAGE |
AFGA | OPERATING TEMP RANGE | -10.0/+50.0 DEG CELSIUS |
AYDW | ACTUATOR TYPE | AXIAL STRESS |