Follow Us on Google+

Request A Price Quote:

Part Number

Part Number:
NSN:
NIIN:
Item Name:
TRANSFORMER , POWER

Definition:

A TRANSFORMER CONSISTING OF ONE OR MORE PRIMARY WINDING(S) AND ONE OR MORE SECONDARY WINDING(S). IT MAY BE DESIGNED FOR DIRECT CONNECTION TO AN ALTERNATING CURRENT SOURCE FOR PURPOSES OF CHANGING THE SECONDARY VOLTS AND AMPERES OR DESIGNED TO ELIMINATE METALLIC INTERCONNECTION BETWEEN CIRCUITS IN AN OVERALL ONE TO ONE VOLTAGE RATIO, WITH OR WITHOUT ADDITIONAL OUTPUT WINDINGS, OR ITEMS DESIGNED TO AUTOMATICALLY MAINTAIN A CONSTANT OUTPUT VOLTAGE WITHIN SPECIFIED LIMITS UNDER VARYING INPUT OR LOAD CONDITIONS. ALSO INCLUDES ITEMS HAVING A PROVISION FOR MECHANICALLY CHANGING THE TURNS RATIO OR INDUCTIVE COUPLING IN PROGRESSIVE INCREMENTS BY MEANS OF VOLTAGE TAPS, RATIO ADJUSTER, OR DEVICES OE SIMILAR DESIGN. FOR TRANSFORMERS HAVING WINDING(S) COMMON TO BOTH INPUT AND OUTPUT CIRCUITS, SEE TRANSFORMER (1), POWER, AUTOTRANSFORMER. EXCLUDES TRANSFORMER (1), PULSE.

CAGE Information

Code Company
08715 CEN ELECTRONICS A DIV OF CHLORIDE PO

Federal Supply Class

Title

COILS AND TRANSFORMERS

Inclusions:

INCLUDES COILS, EXCEPT IGNITION AND MAGNETO; COIL ASSEMBLIES; REACTORS; TRANSFORMERS.

Exclusions:

Characteristics (Decoded)

MRC Requirements Statement Clear Text Reply
AKPV MOUNTING FACILITY QUANTITY 4 SINGLE GROUP
CWJS WINDING OPERATING VOLTAGE 106.00 AC POUNDS PER HOUR DRY SINGLE COMPONENT SINGLE PRIMARY AND 122.00 AC POUNDS PER HOUR WITH RETAINING CHAIN SINGLE COMPONENT SINGLE PRIMARY
CRBZ WINDING OPERATING CURRENT 260.0 MILLIAMPERES NOMINAL B AND BETTER DROP SIDING SINGLE COMPONENT 2ND SECONDARY
THSD THREAD SERIES DESIGNATOR UNC SINGLE GROUP
AAJF THREAD DIRECTION (NON-CORE) RIGHT-HAND SINGLE GROUP
CRBZ WINDING OPERATING CURRENT 160.0 MILLIAMPERES NOMINAL B AND BETTER DROP SIDING SINGLE COMPONENT 1ST SECONDARY
CQLC WINDING TAP LOCATION (NON-CORE) CENTER TAP SINGLE COMPONENT ALL SECONDARY
AARG RELIABILITY INDICATOR NOT ESTABLISHED
ABKQ CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH 3.438 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
AKNA INCLOSURE TYPE HERMETICALLY SEALED
ADAQ BODY LENGTH 5.875 INCHES NOMINAL
AXGY MOUNTING METHOD THREADED STUD SINGLE GROUP
CQJX NOMINAL THREAD SIZE 0.312 INCHES SINGLE GROUP
BPLC WINDING FUNCTION AND QUANTITY 1 PRIMARY SINGLE COMPONENT AND 2 SECONDARY SINGLE COMPONENT
TTQY TERMINAL TYPE AND QUANTITY 8 STANDOFF INSULATOR
ABKR CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH 4.500 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
CWJS WINDING OPERATING VOLTAGE 492.00 AC POUNDS PER HOUR WET SINGLE COMPONENT 1ST SECONDARY
ACZX WINDING SHIELDING METHOD INTERNAL SHIELD GROUNDED TO INCLOSURE SINGLE COMPONENT
ACZC INPUT-OUTPUT PHASE RELATIONSHIP SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT
AAJD THREAD CLASS (NON-CORE) 2A SINGLE GROUP
CWJS WINDING OPERATING VOLTAGE 2.332 AC MINOR WET SINGLE COMPONENT 2ND SECONDARY
CMLP THREAD QUANTITY PER INCH 18 SINGLE GROUP
ACZB FREQUENCY RATING 55.0 HERTZ MINIMUM SINGLE COMPONENT AND 65.0 HERTZ MAXIMUM SINGLE COMPONENT
ADAU BODY HEIGHT 6.562 INCHES NOMINAL
ADAT BODY WIDTH 4.750 INCHES NOMINAL

Similar Parts

W1774 , W1774 , 5950-00-648-1075 , 5950006481075 , 006481075