Part Number
Part Number:
NSN:
NIIN:
Item Name:
RELAY , ELECTROMAGNETIC
Definition:
A RELAY WHICH IS ACTUATED BY THE EFFECT OF A MAGNETIC FIELD DEVELOPED BY THE CURRENT IN ITS ENERGIZING COIL(S). INCLUDES SOLENOID AND ARMATURE TYPES. EXCLUDES CONTACTOR, MAGNETIC; RELAY, METER MOVEMENT; RELAY, MOTOR DRIVEN; RELAY, REED; RELAY, RESONANT REED; RELAY, ROTARY; AND SWITCH, STEPPING.
CAGE Information
Code | Company |
---|---|
94696 | SE RELAYS LLC MAGNECRAFT DIV SE RELA |
Federal Supply Class
Title
RELAYS AND SOLENOIDS
Inclusions:
INCLUDES ELECTROMAGNETIC ACTUATORS.
Exclusions:
EXCLUDES CONTRACTORS.
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
AKDX | WINDING QUANTITY | 1 |
CWAB | MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 120.0 AC |
AEBV | UNTHREADED MOUNTING HOLE DIAMETER | 0.316 INCHES NOMINAL SINGLE MOUNTING FACILITY |
TTQY | TERMINAL TYPE AND QUANTITY | 2 SCREW ENERGIZING ELEMENT |
ABKW | OVERALL HEIGHT | 2.312 INCHES NOMINAL |
AJSS | FREQUENCY IN HERTZ | 50.0 MINIMUM AND 60.0 MAXIMUM |
APCN | COIL QUANTITY | 1 |
TTQY | TERMINAL TYPE AND QUANTITY | 6 SCREW CONTACTS |
ABMK | OVERALL WIDTH | 2.500 INCHES NOMINAL |
CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 10.0 AMPERES AC RESISTIVE LOAD |
CRNG | NONPILE-UP MAIN CONTACT ARRANGEMENT | 2 POLE, DOUBLE THROW, DOUBLE BREAK/DOUBLE MAKE, ONE POSITION MOMENTARY |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 1.875 INCHES NOMINAL SINGLE MOUNTING FACILITY |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 2 UNTHREADED HOLE SINGLE MOUNTING FACILITY |
ABHP | OVERALL LENGTH | 3.125 INCHES NOMINAL |
APNP | DUTY TYPE | CONTINUOUS |
FEAT | SPECIAL FEATURES | USED ON EQUIPMENT TYPE NUMBER FA9955-1; TI 6850.47, FA 9955, 2A2K1, PG 8-4A/4B |
CSXF | OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP | 120.0 VOLTS -80 DEG FAHRENHEIT TYPE 4F SINGLE WINDING |
CBBL | FEATURES PROVIDED | ARC QUENCHING |
CQYJ | MOUNTING FACILITY PATTERN | IN-LINE SINGLE MOUNTING FACILITY |