Follow Us on Google+

Request A Price Quote:

Part Number

Part Number:
NSN:
NIIN:
Item Name:
CIRCUIT BREAKER

Definition:

A DEVICE WITH MEANS OTHER THAN FUSES FOR AUTOMATICALLY OPENING THE CIRCUIT IN WHICH IT IS INSTALLED WHEN THE CURRENT VARIES FROM THE PREDETERMINED VALUE FOR WHICH THE DEVICE IS SET. MAY INCLUDE PROVISIONS FOR MANUAL OPERATION. AT LEAST ONE SET OF CONTACTS MUST BE IN SERIES WITH THE ACTUATING ELEMENT(S). A COMBINATION OF SEMICONDUCTOR AND PASSIVE DEVICES MAY BE USED IN LIEU OF CONTACTS. FOR AUTOMATICALLY OPERATED ITEMS IN WHICH THE ACTUATING (TRIPPING) ELEMENT AND CONTACTS ARE NOT IN SERIES, SEE RELAY (AS MODIFIED). FOR ITEMS WHICH ARE OPERATED BOTH MANUALLY AND AUTOMATICALLY BUT THE ACTUATING ELEMENTS AND CONTACT ARE NOT IN SERIES, SEE RELAY-SWITCH. EXCLUDES CIRCUIT BREAKER BOX AND MAGNETO "BREAKER" ASSEMBLIES. SEE ALSO SWITCH (AS MODIFIED); AND CONTROLLER.

CAGE Information

Code Company
74193 EATON CORP HEINEMANN PRODUCTS COMMER

Federal Supply Class

Title

CIRCUIT BREAKERS

Inclusions:

INCLUDES CIRCUIT BREAKERS AND CUTOUTS.

Exclusions:

EXCLUDES RELAYS.

Characteristics (Decoded)

MRC Requirements Statement Clear Text Reply
CPSM INTERNAL TRIP RELEASE CONFIGURATION SERIES TRIP ALL LOCATIONS
BBRJ SPECIAL HANDLING FEATURE MAGNETIC
FREQ FREQUENCY IN HERTZ 60.0 SINGLE LOCATION
BBRG STORAGE TYPE GENERAL PURPOSE WAREHOUSE
CPRJ TRIP RELEASE METHOD MAGNETIC-HYDRAULIC SINGLE LOCATION
CPRH CIRCUIT PROTECTION TYPE OVERCURRENT SINGLE LOCATION
AAQL BODY STYLE SINGLE POLE TYPE
AFJN FRAGILITY FACTOR MODERATELY RUGGED
CPRG MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS 5000.0 AC SINGLE LOCATION
CPRR MAIN CONTACT TRIPPING MECHANISM TYPE TRIP FREE
AEBP CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH 4.380 INCHES NOMINAL
ADAU BODY HEIGHT 2.830 INCHES NOMINAL
ADTV CASE MATERIAL PLASTIC
AKPX POLE QUANTITY 1
CPRQ RESET METHOD MANUAL
CPLM MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE 30.0 AMPERES AC SINGLE LOCATION
AEBY DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH 2.750 INCHES NOMINAL
ADAQ BODY LENGTH 4.750 INCHES NOMINAL
AXHR MOUNTING FACILITY TYPE AND QUANTITY 2 THREADED HOLE
THSD THREAD SERIES DESIGNATOR UNC
PKWT UNPACKAGED UNIT WEIGHT 0.688 POUNDS
TTQY TERMINAL TYPE AND QUANTITY 2 BUS BAR
CQWN TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT 40.000 MINIMUM AT 200 PCT SINGLE LOCATION AND 100.500 MAXIMUM AT 200 PCT SINGLE LOCATION
CPRW ACTUATOR FUNCTION TRIP-RESET
APNQ ARC QUENCHING METHOD MAGNETIC BLOWOUT
CPRX ACTUATOR POSITION DESIGNATION AT POLE ONE
CPRT MANUAL ACTUATOR TYPE AND QUANTITY 1 TOGGLE
ADAT BODY WIDTH 1.030 INCHES NOMINAL
CMLP THREAD QUANTITY PER INCH 32
CPRL TRIP RELEASE CHARACTERISTIC TIME DELAY SINGLE LOCATION
CPRF OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS 120.0 AC SINGLE LOCATION
CPRN ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT 125.0 SINGLE LOCATION
CQXF INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED GENERAL PURPOSE
CQJX NOMINAL THREAD SIZE 0.138 INCHES

Similar Parts

X0411-30-120VAC60-1 , X041130120VAC601 , 5925-00-581-0393 , 5925005810393 , 005810393