Follow Us on Google+

Request A Price Quote:

Part Number

Part Number:
NSN:
NIIN:
Item Name:
TRANSFORMER , PULSE

Definition:

A TRANSFORMER DESIGNED TO TRANSFER PULSES OF NONSINUSOIDAL WAVE FORMS BETWEEN CIRCUITS WITHOUT BASICALLY CHANGING THE WAVE FORMS.

CAGE Information

Code Company
90095 PULSE ELECTRONICS DBA PULSE COMPONEN

Federal Supply Class

Title

COILS AND TRANSFORMERS

Inclusions:

INCLUDES COILS, EXCEPT IGNITION AND MAGNETO; COIL ASSEMBLIES; REACTORS; TRANSFORMERS.

Exclusions:

Characteristics (Decoded)

MRC Requirements Statement Clear Text Reply
AKNA INCLOSURE TYPE FULLY INCLOSED
ABKW OVERALL HEIGHT 0.300 INCHES MAXIMUM
ABMK OVERALL WIDTH 0.810 INCHES MAXIMUM
CRGS DC RESISTANCE RATING IN OHMS 2.100 SINGLE COMPONENT SINGLE PRIMARY
CWJS WINDING OPERATING VOLTAGE 2.00 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE PRIMARY
ACZB FREQUENCY RATING 10.0 KILOHERTZ NOMINAL SINGLE COMPONENT
AARG RELIABILITY INDICATOR NOT ESTABLISHED
AEHZ MAXIMUM OPERATING TEMP 130.0 DEG CELSIUS
TTQY TERMINAL TYPE AND QUANTITY 9 WIRE LEAD
CRGS DC RESISTANCE RATING IN OHMS 0.955 SINGLE COMPONENT SINGLE SECONDARY
CQLC WINDING TAP LOCATION (NON-CORE) CENTER TAP SINGLE COMPONENT SINGLE PRIMARY
BPLC WINDING FUNCTION AND QUANTITY 1 PRIMARY SINGLE COMPONENT AND 1 SECONDARY SINGLE COMPONENT
ACZX WINDING SHIELDING METHOD INTERNAL SHIELD BROUGHT OUT TO TERMINAL SINGLE COMPONENT
PKWT UNPACKAGED UNIT WEIGHT (NON-CORE) 8.0 GRAMS
TEST TEST DATA DOCUMENT 88818-A504A573 DRAWING
ADAQ BODY LENGTH 0.810 INCHES MAXIMUM
AXGY MOUNTING METHOD TERMINAL SINGLE GROUP
CQLC WINDING TAP LOCATION (NON-CORE) MULTIPLE TAPS W/CENTER TAP SINGLE COMPONENT SINGLE SECONDARY
CWJS WINDING OPERATING VOLTAGE 1.20 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE SECONDARY AND 0.50 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE SECONDARY AND 1.41 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE SECONDARY

Similar Parts

X1405-1 , X14051 , 5950-01-339-0329 , 5950013390329 , 013390329