Part Number
Definition:
A RIGID OR FLEXIBLE TUBING HAVING UNIFORM INSIDE AND OUTSIDE DIAMETERS IN THE OVERALL LENGTH. IT IS SPECIFICALLY DESIGNED TO PREVENT ANY UNDESIRABLE FLOW OF CURRENT BETWEEN CONDUCTORS AND OTHER OBJECTS. INCLUDES SHRINKABLE TYPE TUBING, ITEMS IN BULK AND IN SPECIFIC FABRICATED LENGTHS (CUT TO SIZE). EXCLUDES ITEMS NOT HAVING RATED ELECTRICAL CHARACTERISTICS. ALSO EXCLUDES BUSHING, SLEEVE; CABLE NIPPLE, ELECTRICAL; CONDUIT (AS MODIFIED); INSULATION SLEEVING, ELECTRICAL, SPECIAL PURPOSE; INSULATION SLEEVING, THERMAL; SLEEVE, MARKER, CABLE; SLEEVING, TEXTILE, ELECTRICAL; TUBING, GLASS; AND TUBING, NONMETALLIC.
CAGE Information
Code | Company |
---|---|
88818 | KEARFOTT CORPORATION DBA KEARFOTT DI |
Federal Supply Class
Title
ELECTRICAL INSULATORS AND INSULA
Inclusions:
INCLUDES TUBE, KNOB, CLEAT, STRAIN, AND STANDOFF INSULATORS; FEED THRU INSULATORS; BEAD INSULATORS; VARNISH CAMBRIC TAPE; FRICTION TAPE.
Exclusions:
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
HUES | COLOR | NATURAL |
AAGT | WALL THICKNESS | 0.009 INCHES NOMINAL |
ABHP | OVERALL LENGTH | ANY ACCEPTABLE |
UKBG | DIELECTRIC MATERIAL VOLTAGE RATING PER UNIT THICKNESS | 2000.0 VOLTS PER MIL /0.001 INCH/ |
AARX | INSIDE DIAMETER | 0.015 INCHES NOMINAL |
CQBC | MINIMUM TENSILE STRENGTH | 6500 POUNDS PER SQUARE INCH |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
ABJH | TEMP RATING | -100.0 DEG CELSIUS AND 150.0 DEG CELSIUS |
MATL | MATERIAL | PLASTIC, ETHYLENE TETRAFLUOROETHYLENE FLUOROPOLYMER /TEFZEL/ E. I. DUPONT DENEMOURS AND CO. INC. |
STYL | STYLE DESIGNATOR | NONSHRINKABLE |
FLEX | FLEXIBILITY | SEMIRIGID |