Part Number
Part Number:
NSN:
NIIN:
Item Name:
RELAY , ELECTROMAGNETIC
Definition:
A RELAY WHICH IS ACTUATED BY THE EFFECT OF A MAGNETIC FIELD DEVELOPED BY THE CURRENT IN ITS ENERGIZING COIL(S). INCLUDES SOLENOID AND ARMATURE TYPES. EXCLUDES CONTACTOR, MAGNETIC; RELAY, METER MOVEMENT; RELAY, MOTOR DRIVEN; RELAY, REED; RELAY, RESONANT REED; RELAY, ROTARY; AND SWITCH, STEPPING.
CAGE Information
Code | Company |
---|---|
58657 | LEACH INTERNATIONAL CORPORATION DBA |
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
AKDX | WINDING QUANTITY | 1 |
TTQY | TERMINAL TYPE AND QUANTITY | 2 THREADED STUD ENERGIZING ELEMENT |
CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 30.0 AMPERES DC INDUCTIVE LOAD |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 2.875 INCHES NOMINAL SINGLE MOUNTING FACILITY |
CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 50.0 AMPERES DC RESISTIVE LOAD |
AEBV | UNTHREADED MOUNTING HOLE DIAMETER | 0.213 INCHES MINIMUM SINGLE MOUNTING FACILITY AND 0.228 INCHES MAXIMUM SINGLE MOUNTING FACILITY |
APCN | COIL QUANTITY | 1 |
ADAV | OVERALL DIAMETER | 3.650 INCHES MAXIMUM |
FEAT | SPECIAL FEATURES | OPERATING TEMPERATURE MINUS 55.0 TO PLUS 85.0 DEGREES C |
CBBL | FEATURES PROVIDED | POLARIZED |
CRXH | TIME DELAY | 0.06 SECONDS NOMINAL FIXED OPERATE TIME |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 4 UNTHREADED HOLE SINGLE MOUNTING FACILITY |
ABHP | OVERALL LENGTH | 4.280 INCHES MAXIMUM |
CRNG | NONPILE-UP MAIN CONTACT ARRANGEMENT | 3 POLE, DOUBLE THROW, ONE POSITION MOMENTARY |
CSXF | OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP | 28.0 VOLTS DC 25 DEG CELSIUS SINGLE WINDING |
CWAB | MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 29.0 DC |
ADZC | ENVIRONMENTAL PROTECTION | HERMETIC |
TTQY | TERMINAL TYPE AND QUANTITY | 9 THREADED STUD CONTACTS |
CRXH | TIME DELAY | 0.04 SECONDS NOMINAL FIXED RELEASE TIME |
APNP | DUTY TYPE | CONTINUOUS |
APNA | WINDING DC RESISTANCE RATING | 113.0 OHMS NOMINAL SINGLE WINDING |
CQYJ | MOUNTING FACILITY PATTERN | RECTANGULAR SINGLE MOUNTING FACILITY |