NIIN Output Data
NIIN:
NSN:
Item Name:
RELAY , ELECTROMAGNETIC
Definition:
A RELAY WHICH IS ACTUATED BY THE EFFECT OF A MAGNETIC FIELD DEVELOPED BY THE CURRENT IN ITS ENERGIZING COIL(S). INCLUDES SOLENOID AND ARMATURE TYPES. EXCLUDES CONTACTOR, MAGNETIC; RELAY, METER MOVEMENT; RELAY, MOTOR DRIVEN; RELAY, REED; RELAY, RESONANT REED; RELAY, ROTARY; AND SWITCH, STEPPING.
Reference/Part Number
Part Number | CAGE | Status | RNCC | RNVC | DAC | RNAAC | MSDS | SADC |
---|---|---|---|---|---|---|---|---|
IC5182C120A3AAAA | 1DUQ5 | F | 5 | 9 | E | TX | ||
IC5182C120A3AAAA | 01526 | H | 5 | 9 | E | TX | ||
1C5182C120A3AAAA | 02295 | A | 5 | 9 | 5 | TX | ||
053023-0-01 | 96169 | A | 3 | 2 | 5 | ZZ | ||
IC5182C120A3AAAA | 02989 | A | 5 | 2 | 5 | ZZ | ||
053023-0-01 | 95402 | H | 5 | 9 | 1 | TX |
CAGE Information
Code | Company |
---|---|
01526 | GENICOM CORP |
1DUQ5 | COMMUNICATIONS INSTRUMENTS INC DIV O |
02295 | GENERAL ELECTRIC CO GENERAL PURPOSE |
96169 | ELECTRIC BOAT CORPORATION |
02989 | GENERAL ELECTRIC CO GE DRIVE SYSTEMS |
95402 | ELECTRIC BOAT CORP DBA ELECTRO DYNAM |
Federal Supply Class
Title
RELAYS AND SOLENOIDS
Inclusions:
INCLUDES ELECTROMAGNETIC ACTUATORS.
Exclusions:
EXCLUDES CONTRACTORS.
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
AKDX | WINDING QUANTITY | 1 |
ABKW | OVERALL HEIGHT | 6.750 INCHES NOMINAL |
TTQY | TERMINAL TYPE AND QUANTITY | 18 SCREW ALL FUNCTIONS |
ABHP | OVERALL LENGTH | 6.375 INCHES NOMINAL |
AJSS | FREQUENCY IN HERTZ | 60.0 NOMINAL |
APCN | COIL QUANTITY | 1 |
CSXF | OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP | 115.0 VOLTS -80 DEG FAHRENHEIT TYPE 4F SINGLE WINDING |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 4 UNTHREADED HOLE SINGLE MOUNTING FACILITY |
CRNG | NONPILE-UP MAIN CONTACT ARRANGEMENT | 4 POLE, SINGLE THROW, NORMALLY OPEN, MOMENTARY ACTION AND 4 POLE, SINGLE THROW, NORMALLY CLOSED, MOMENTARY ACTION |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 4.000 INCHES NOMINAL SINGLE MOUNTING FACILITY |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 4.000 INCHES NOMINAL SINGLE MOUNTING FACILITY |
APNP | DUTY TYPE | CONTINUOUS |
CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 10.0 AMPERES AC RESISTIVE LOAD AND 10.0 AMPERES DC RESISTIVE LOAD |
ABMK | OVERALL WIDTH | 5.000 INCHES NOMINAL |
CWAB | MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 115.0 AC AND 115.0 DC |
AEBV | UNTHREADED MOUNTING HOLE DIAMETER | 0.219 INCHES NOMINAL SINGLE MOUNTING FACILITY |
CQYJ | MOUNTING FACILITY PATTERN | RECTANGULAR SINGLE MOUNTING FACILITY |