Follow Us on Google+

Request A Price Quote:

Part Number

Part Number:
NSN:
NIIN:
Item Name:
RELAY , ELECTROMAGNETIC

Definition:

A RELAY WHICH IS ACTUATED BY THE EFFECT OF A MAGNETIC FIELD DEVELOPED BY THE CURRENT IN ITS ENERGIZING COIL(S). INCLUDES SOLENOID AND ARMATURE TYPES. EXCLUDES CONTACTOR, MAGNETIC; RELAY, METER MOVEMENT; RELAY, MOTOR DRIVEN; RELAY, REED; RELAY, RESONANT REED; RELAY, ROTARY; AND SWITCH, STEPPING.

CAGE Information

Code Company
01526 GENICOM CORP

Federal Supply Class

Title

RELAYS AND SOLENOIDS

Inclusions:

INCLUDES ELECTROMAGNETIC ACTUATORS.

Exclusions:

EXCLUDES CONTRACTORS.

Characteristics (Decoded)

MRC Requirements Statement Clear Text Reply
AKDX WINDING QUANTITY 1
ABKW OVERALL HEIGHT 6.750 INCHES NOMINAL
TTQY TERMINAL TYPE AND QUANTITY 18 SCREW ALL FUNCTIONS
ABHP OVERALL LENGTH 6.375 INCHES NOMINAL
AJSS FREQUENCY IN HERTZ 60.0 NOMINAL
APCN COIL QUANTITY 1
CSXF OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP 115.0 VOLTS -80 DEG FAHRENHEIT TYPE 4F SINGLE WINDING
AXHR MOUNTING FACILITY TYPE AND QUANTITY 4 UNTHREADED HOLE SINGLE MOUNTING FACILITY
CRNG NONPILE-UP MAIN CONTACT ARRANGEMENT 4 POLE, SINGLE THROW, NORMALLY OPEN, MOMENTARY ACTION AND 4 POLE, SINGLE THROW, NORMALLY CLOSED, MOMENTARY ACTION
ABKR CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH 4.000 INCHES NOMINAL SINGLE MOUNTING FACILITY
ABKQ CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH 4.000 INCHES NOMINAL SINGLE MOUNTING FACILITY
APNP DUTY TYPE CONTINUOUS
CTDL MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE 10.0 AMPERES AC RESISTIVE LOAD AND 10.0 AMPERES DC RESISTIVE LOAD
ABMK OVERALL WIDTH 5.000 INCHES NOMINAL
CWAB MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS 115.0 AC AND 115.0 DC
AEBV UNTHREADED MOUNTING HOLE DIAMETER 0.219 INCHES NOMINAL SINGLE MOUNTING FACILITY
CQYJ MOUNTING FACILITY PATTERN RECTANGULAR SINGLE MOUNTING FACILITY

Similar Parts

IC5182C120A3AAAA , IC5182C120A3AAAA , 5945-01-064-2728 , 5945010642728 , 010642728